Starting in IDS 12.3, most, if not all, new/upgraded Xilinx IP cores will only use AXI as user interface. For FFT v8.0 specifically, it provides AXI4-Stream interfaces for input/output data and control. The AXI4-stream interface is a lot simpler than memory mapped AXI4 interface. It uses basic handshake between the master and slave as shown in the snapshot below from the FFT v8.0 Data Sheet (note that all AXI IP cores have separate data sheets than the non-AXI versions). The key thing to remember is that the AXI payload is only transferred when both TVALID and TREADY are high.
I updated the SysGen example in the blog FFT results from Matlab fft, Bit Accurate C model and SysGen FFT block with FFT v8.0 core to show the use of AXI4 stream interface. Below is the updated SysGen model:
The updated SysGen model and m file can be downloaded from here. Again, you will need to download the bit accurate model from FFT core web site yourself to run fft_compare.m script.
Wednesday, December 8, 2010
Thursday, November 11, 2010
Understand maximum frequency reporting in XST
Let's say your design has a single 50MHz clock source coming in. It then goes to a DCM or PLL to generate three clock outputs at 50MHz, 100MHz and 150MHz. When you run through synthesis XST reports the maximum frequency of the design like below.
Tuesday, October 12, 2010
Use Excel to Draw Waveforms
I learned a trick yesterday from a friend's tweet that Excel can be used to draw waveforms using different cell border outlines. I just tried it out and within a few minutes I got a pretty nice waveform in front of me. There is no learning curve involved and no need to purchase and/or install a special waveform drawing tool. I presume OpenOffice Calc can be used to do the same thing.
Below is the waveform in Excel:
And here how it looks like in "Print Preview":
Below is the waveform in Excel:
And here how it looks like in "Print Preview":
Thursday, July 22, 2010
DDS in System Generator: how to set up periods?
If you use DDS Compiler in System Generator, you will notice there are 4 clock periods you need to deal with (circled in red in the snapshot below). This can be confusing for first time users. Hopefully this blog can clear up some of the confusions.
Test1:
FPGA clock period (ns) = 10
Simulink system period = 1
DDS System Clock (MHz) = 100
Use Explicit Sample Period checked and Explicit Period = 1
DDS Output (MHz) = 1
As shown in the scope below the DDS output matches the SineGen output:
Test2:
FPGA clock period (ns) = 10
Simulink system period = 0.1
DDS System Clock (MHz) = 100
Use Explicit Sample Period checked and Explicit Period = 0.1
DDS Output (MHz) = 1
As shown in the scope below the DDS output matches the SineGen output. Note that the Simulink system period is now 1/10th of the period in Test1, so there are 10x more clock cycles in this test with the same simulation time.
Test3:
FPGA clock period (ns) = 10
Simulink system period = 0.1
DDS System Clock (MHz) = 100
Use Explicit Sample Period unchecked
DDS Output (MHz) = 1
As shown in the scope below the DDS output frequency is 1/10th of SinGen output. The incorrect DDS output frequency is caused by that when "Use Explicit Sample Period" is unchecked Simulink use a sample period of 1 for the DDS block. So it's very important to check this checkbox and set the explicit period to match the Simulink system period if it's not 1. It's worth mentioning that for sampling frequency related issues it's very helpful to turn on "Sample Time Display" (under Format menu) and then update the diagram by pressing CTRL-D. You can easily see if the sample time used for a particular is correct with sampling time displayed on all signals.
- FPGA clock period (ns): only used for FPGA synthesis and implementation. This value does NOT affect simulation in Simulink (i.e. it will NOT affect output frequency of the DDS block).
- Simulink System Period: only used in Simulink simulation. This is the lowest sampling period (highest sampling frequency) among all blocks in the model. There is no significance in its absolute value as long as the sampling periods of all other blocks are multiple of the Simulink System Period. Usually it is set to 1 to keep everything simple. (e.g. every tick in a scope is 1 clock cycle).
- DDS System Clock (Mhz): It's used to calculate the phase increment for DDS block (see the DDS datasheet for details). Set it to match the FPGA clock period (i.e. DDS System Clock (Mhz) = 1/FPGA clock period).
- Explicit Sample Period: This is the sample period used for the DDS block. IMPORTANT: if you set Simulink System Period to anything other than 1, "Use explicit period" MUST be checked and "Explicit Period" set to the same value as Simulink System period. Otherwise, Simulink will use the sample period of 1 for the DDS core and the output frequency will be wrong. This is likely a bug.
Test1:
FPGA clock period (ns) = 10
Simulink system period = 1
DDS System Clock (MHz) = 100
Use Explicit Sample Period checked and Explicit Period = 1
DDS Output (MHz) = 1
As shown in the scope below the DDS output matches the SineGen output:
Test2:
FPGA clock period (ns) = 10
Simulink system period = 0.1
DDS System Clock (MHz) = 100
Use Explicit Sample Period checked and Explicit Period = 0.1
DDS Output (MHz) = 1
As shown in the scope below the DDS output matches the SineGen output. Note that the Simulink system period is now 1/10th of the period in Test1, so there are 10x more clock cycles in this test with the same simulation time.
Test3:
FPGA clock period (ns) = 10
Simulink system period = 0.1
DDS System Clock (MHz) = 100
Use Explicit Sample Period unchecked
DDS Output (MHz) = 1
As shown in the scope below the DDS output frequency is 1/10th of SinGen output. The incorrect DDS output frequency is caused by that when "Use Explicit Sample Period" is unchecked Simulink use a sample period of 1 for the DDS block. So it's very important to check this checkbox and set the explicit period to match the Simulink system period if it's not 1. It's worth mentioning that for sampling frequency related issues it's very helpful to turn on "Sample Time Display" (under Format menu) and then update the diagram by pressing CTRL-D. You can easily see if the sample time used for a particular is correct with sampling time displayed on all signals.
Tuesday, July 13, 2010
FFT: Valid Values of Number of Stages Using Block RAM
If you have used the FFT block in System Generator, you probably have seen the error message below.
You've got to love these "you-did-something-wrong-but-I-am-not-gonna-tell-you-how-to-fix-it" error messages. If you read through the datasheet, you will find it's not any better as it asks you to run Core Generator to get the valid values for the FFT transform length you chose. I've gone through this quite a few times, so I put together the table below showing valid values of "Number of Stages Using Block RAM" for all supported FFT sizes (data extracted from CoreGen 12.1) for me to use it as a quick reference. I hope this will also save other people a few minutes by not having to run CoreGen to get this simple info which should have been clearly stated in the error message.
You've got to love these "you-did-something-wrong-but-I-am-not-gonna-tell-you-how-to-fix-it" error messages. If you read through the datasheet, you will find it's not any better as it asks you to run Core Generator to get the valid values for the FFT transform length you chose. I've gone through this quite a few times, so I put together the table below showing valid values of "Number of Stages Using Block RAM" for all supported FFT sizes (data extracted from CoreGen 12.1) for me to use it as a quick reference. I hope this will also save other people a few minutes by not having to run CoreGen to get this simple info which should have been clearly stated in the error message.
| FFT Size | Number of Stages Using Block RAM |
|---|---|
| 8 | 0 |
| 16 | 0 |
| 32 | 0 |
| 64 | 0-1 |
| 128 | 0-2 |
| 256 | 0-3 |
| 512 | 0-4 |
| 1024 | 1-5 |
| 2048 | 2-6 |
| 4096 | 3-7 |
| 8192 | 4-8 |
| 16384 | 5-9 |
| 32768 | 6-10 |
| 65536 | 7-11 |